Setting up A Transformer in Proteus


The calculation Formula is  L1/L2 = (V1/V2)^2

For Example: Design for 6 Volt input ,230volt 50Hz Not considered wattage just for simulation. 

           Assign L1 = 1H (but 1henry expectable for a 10 or 20 kW transformer)

        Then L2 = 1/(230/6)^2
                       = 680.5293micro Henry